.. _opal-api-LEDs:
|
|
|
|
Service Indicators (LEDS)
|
|
=========================
|
|
|
|
The service indicator is one element of an overall hardware service strategy
|
|
where end user simplicity is a high priority. The goal is system firmware or
|
|
operating system code to isolate hardware failures to the failing FRU and
|
|
automatically activate the fault indicator associated with the failing FRU.
|
|
The end user then needs only to look for the FRU with the active fault
|
|
indicator to know which part to replace.
|
|
|
|
Different types of indicators handled by LED code:
|
|
|
|
- System attention indicator (Check log indicator)
|
|
Indicates there is a problem with the system that needs attention.
|
|
- Identify
|
|
Helps the user locate/identify a particular FRU or resource in the
|
|
system.
|
|
- Fault
|
|
Indicates there is a problem with the FRU or resource at the
|
|
location with which the indicator is associated.
|
|
|
|
All LEDs are defined in the device tree (see :ref:`device-tree/ibm,opal/leds`).
|
|
|
|
LED Design
|
|
----------
|
|
When it comes to implementation we can classify LEDs into two
|
|
categories:
|
|
|
|
1. Hypervisor (OPAL) controlled LEDs (All identify & fault indicators)
|
|
During boot, we read/cache these LED details in OPAL (location code,
|
|
state, etc). We use cached data to serve read request from FSP/Host.
|
|
And we use SPCN passthrough MBOX command to update these LED state.
|
|
|
|
2. Service processor (FSP) controlled LEDs (System Attention Indicator)
|
|
During boot, we read/cache this LED info using MBOX command. Later
|
|
anytime FSP updates this LED, it sends update system parameter
|
|
notification MBOX command. We use that data to update cached data.
|
|
LED update request is sent via set/reset attn MBOX command.
|
|
|
|
LED update request:
|
|
Both FSP and Host will send LED update requests. We have to serialize
|
|
SPCN passthrough command. Hence we maintain local queue.
|
|
|
|
Note:
|
|
|
|
- For more information regarding service indicator refer to PAPR spec
|
|
(Service Indicators chapter).
|
|
|
|
There are two OPAL calls relating to LED operations.
|
|
|
|
.. _OPAL_LEDS_GET_INDICATOR:
|
|
|
|
OPAL_LEDS_GET_INDICATOR
|
|
-----------------------
|
|
|
|
.. code-block:: c
|
|
|
|
#define OPAL_LEDS_GET_INDICATOR 114
|
|
|
|
int64_t opal_leds_get_indicator(char *loc_code, u64 *led_mask,
|
|
u64 *led_value, u64 *max_led_type);
|
|
|
|
Returns LED state for the given location code.
|
|
|
|
``loc_code``
|
|
Location code of the LEDs.
|
|
``led_mask``
|
|
LED types whose status is available (return by OPAL)
|
|
``led_value``
|
|
Status of the available LED types (return by OPAL)
|
|
``max_led_type``
|
|
Maximum number of supported LED types (Host/OPAL)
|
|
|
|
The host will pass the location code of the LED types (loc_code) and
|
|
maximum number of LED types it understands (max_led_type). OPAL will
|
|
update the 'led_mask' with set bits pointing to LED types whose status
|
|
is available and updates the 'led_value' with actual status. OPAL checks
|
|
the 'max_led_type' to understand whether the host is newer or older
|
|
compared to itself. In the case where the OPAL is newer compared
|
|
to host (OPAL's max_led_type > host's max_led_type), it will update
|
|
led_mask and led_value according to max_led_type requested by the host.
|
|
When the host is newer compared to the OPAL (host's max_led_type >
|
|
OPAL's max_led_type), OPAL updates 'max_led_type' to the maximum
|
|
number of LED type it understands and updates 'led_mask', 'led_value'
|
|
based on that maximum value of LED types.
|
|
|
|
Currently this is only implemented on FSP basde machines, see
|
|
hw/fsp/fsp-leds.c for more deatails.
|
|
|
|
.. _OPAL_LEDS_SET_INDICATOR:
|
|
|
|
OPAL_LEDS_SET_INDICATOR
|
|
-----------------------
|
|
|
|
.. code-block:: c
|
|
|
|
#define OPAL_LEDS_SET_INDICATOR 115
|
|
|
|
int64_t opal_leds_set_indicator(uint64_t async_token,
|
|
char *loc_code, const u64 led_mask,
|
|
const u64 led_value, u64 *max_led_type);
|
|
|
|
Sets LED state for the given location code.
|
|
|
|
``loc_code``
|
|
Location code of the LEDs to be set.
|
|
``led_mask``
|
|
LED types whose status will be updated
|
|
``led_value``
|
|
Requested status of various LED types.
|
|
``max_led_type``
|
|
Maximum number of supported LED types. If OPAL supports fewer LED types
|
|
than requested, it will set ``max_led_type`` to the maximum it does support.
|
|
|
|
The host will pass the location code of the LED types, mask, value
|
|
and maximum number of LED types it understands. OPAL will update
|
|
LED status for all the LED types mentioned in the mask with their
|
|
value mentioned. OPAL checks the 'max_led_type' to understand
|
|
whether the host is newer or older compared to itself. In case where
|
|
the OPAL is newer compared to the host (OPAL's max_led_type >
|
|
host's max_led_type), it updates LED status based on max_led_type
|
|
requested from the host. When the host is newer compared to the OPAL
|
|
(host's max_led_type > OPAL's max_led_type), OPAL updates
|
|
'max_led_type' to the maximum number of LED type it understands and
|
|
then it updates LED status based on that updated maximum value of LED
|
|
types. Host needs to check the returned updated value of max_led_type
|
|
to figure out which part of it's request got served and which ones got
|
|
ignored.
|
|
|
|
Currently this is only implemented on FSP basde machines, see
|
|
hw/fsp/fsp-leds.c for more deatails.
|